Stuart-turner Techflo TP 60TNH Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pompy Stuart-turner Techflo TP 60TNH. Stuart Turner Techflo TP 60TNH User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the home owner as it contains
important guarantee, maintenance and safety information
Read this manual carefully before commencing installation.
This manual covers the following products:
TP60 SNH
Pt. No. 49003
TP60 TNH
Pt. No. 49002
FOR POSITIVE OR NEGATIVE HEAD APPLICATIONS
*1 year as standard extended to 2 years with a Techflange fitted
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - Instructions

Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the home owner as it contains important guarantee, ma

Strona 2 - CONTENTS Page

- 10 -Cont ...3.12 Hose to pump: The pump inlet and outlet ports have fittings which are specifically designed for connection to the G ¾ femal

Strona 3 - 22 mm outlet pipework

- 11 -Cont ... 2. Prior to inserting pipe into fitting, mark the insert depth on the wall of the pipe with a soft pencil at a distance of 31 m

Strona 4

- 12 -Cont ...If you have any concern either about using push-in fittings or should the joint leak on final test, isolate the water supplies and conta

Strona 5 - 2 LOCATION - GENERAL

- 13 -Cont ...4 ELECTRICAL INSTALLATION4.11 Regulations: The electrical installation must be carried out in accordance with the current natio

Strona 6 - 2 LOCATION - TWIN PUMP

- 14 -Cont ... The wire which is coloured green and yellow must be connected to the terminal in the connection unit which is marked with the lett

Strona 7

- 15 -Cont ...4.24 Cable Gland Fitting Instructions: To enable correct assembly of the cable gland the ‘O’-ring (Fig. 16 item 1) must be placed

Strona 8 - Fig. 6 - Single Pump

- 16 -Cont ...5 COMMISSIONING5.11 System Flushing: This pump incorporates push-in connectors and plastic components that must not come into cont

Strona 9 - 3 PUMP CONNECTIONS

- 17 -Cont ...6 MAINTENANCE6.11 Isolate the unit from the electrical supply before commencing any work. 6.12 Turn off water supplies to the pump a

Strona 10 - Cont

- 18 -Cont ...6.14 Water scale: As water is heated scale deposits are released in areas of hard water, scale can cause the mechanical seal to

Strona 11

- 19 -Cont ...Techflow Products reserve the right to amend the specification in line with its policy of continuous development of its products.Note:

Strona 12

- 2 -PRODUCT DESCRIPTIONElectric motor driven single or twin ended peripheral pumps complete with an automatic control system, consisting of flow swit

Strona 13 - 4 ELECTRICAL INSTALLATION

- 20 -8 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check power supply.Check fuse (see fu

Strona 14 - Twin Pumps

- 21 -Cont ...8.11 Dry Run Protection: This pump is fitted with a PCB that will detect the following fault conditions:  Dry running caused by wat

Strona 15 - Fig. 16

- 22 -Cont ... IMPORTANT – Ensure there is no contact with any of the internal parts of the terminal box.  Briefly reconnect the mains power su

Strona 16 - 5 COMMISSIONING

- 23 -Cont ...8.14 Flow Switch Circuit Test: 1. First confirm visually that the flow switch reed clamps have not been dislodged during handl

Strona 17 - 6 MAINTENANCE

- 24 -9 THE TECHFLOW GUARANTEECongratulations on purchasing a Techflow pump. We are confident this pump will provide many years of trouble free servi

Strona 18

- 25 -NOTES

Strona 21

Techfl ow Products, Service Department, Greys Road, Henley-on-Thames, Oxfordshire RG9 1RY ENGLAND Tel: +44 (0) 1444 258017, Fax: +44 (0) 1444

Strona 22 - Retaining screws x 4

- 3 -Your product may vary slightly from the picture above.PRE-INSTALLATION CHECKThe pressure vessel is supplied as a separate item, and will need to

Strona 23 - Reed Clamp

- 4 -1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity must be sufficient to meet th

Strona 24 - 01444 258017

- 5 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must

Strona 25

- 6 -Cont ...2 LOCATION - SINGLE PUMPCold water connection:2.27 The cold water supply: The supply must be AIR FREE and have a DEDICATED CONN

Strona 26

- 7 -Cont ...Hot water connection:2.28 Hot water cylinder or storage tank: When a hot water cylinder or storage tank is used, ensure the pipewor

Strona 27

- 8 -Cont ...2.32 Non-preferred pump location: If it is not possible to locate the pump in the preferred area due to site limitations and it is

Strona 28 - Business Development Director

- 9 -Cont ...3 PUMP CONNECTIONS  Do not use stainless steel, chrome or nickel plated pipe with the flexible hose push-in plumbing connections.