- 15 -
Cont ...
4.24 Cable Gland Fitting Instructions:
To enable correct assembly of the cable gland the ‘O’-ring (Fig. 16 item 1) must
be placed over the cable before the clamping insert (Fig. 16 item 2) can be
tightened.
Note: Cable diameter range:- 6.5 mm to 9.5 mm.
4.25 Supply Cord Extension:
The pumps are fitted with a supply cord to the following specification:-
All models . . . . . . . . . . . . . . . . .HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be
used. Any connections or junction boxes used should be specifically suited for
the application and installed in accordance with the manufacturers instructions.
Fig. 16
1